Product Introduction|Hikelok Seamless Dielectric Fitting

In oil-gas and chemical sites, instrument impulse piping operates under conditions of high pressure, vibration and medium erosion. Cathodic-protection current and stray current can easily trigger electrochemical corrosion of instruments and drift of measurement signals, which may impair stable operation of the whole plant in severe cases. Selecting reliable dielectric insulating fittings is a non-negligible part of engineering component selection.

DF-2

1. Product Overview

Hikelok seamless dielectric fittings electrically isolate monitoring instruments from current interference.

Widely applied to impulse‑monitoring piping for oil & gas pipelines, especially for front-end impulse lines at natural-gas pipeline monitoring stations. It blocks electric current while permitting normal flow of process media.

The product adopts a split-type structure with separated insulation and sealing functions. High‑performance polymer insulators deliver stable dielectric performance under diverse operating conditions and climates; built-in FKM fluorocarbon O-rings provide primary fluid sealing.

 

2. Product Features

DF-1

Patented seamless dielectric fitting
Utility Model Patent: A seamless dielectric fitting with Minimized Leak Points (ZL 2016 2 0966934.5)

*Insulator resistance @70 °F (20 °C): 100 MΩ (at 10 V DC)

*Maximum working pressure: 5000 psig (344 bar)

*Working temperature range: -40 °F ~ 200 °F (-40 °C ~ 93 °C)

*Metallic wetted body: 316 stainless steel

*Insulator material: PAI (Polyamide-imide)

*End connections available: double-ferrule tube fitting, NPT / BSP tapered pipe thread

 

3. Core Product Advantages

Seamless patented one-piece flow path for enhanced sealing durability

Most conventional dielectric fittings adopt welded construction. Weld seams and their heat-affected zones tend to generate burrs and residual welding stress, and are susceptible to intergranular corrosion. Weld seams represent inherent leak-prone weak points; defects will propagate under alternating pressure and medium erosion and reduce long-term service reliability.

Hikelok dielectric fitting features an integral, seamless flow path design, eliminating heat-affected zones, weld burrs and welding residual stress associated with welding processes. The smooth internal bore removes weld-induced burrs, minimizing medium stagnation, particle accumulation and localized electrochemical-corrosion risks. It also eliminates weld-related leakage sources, reduces potential piping leak points and improves structural stability under high-pressure and alternating-pressure service. It is particularly suitable for oil-gas transmission, instrument sampling, chemical-media delivery and other applications requiring high piping cleanliness and sealing integrity.

Separated functional design avoids dual-mode failure

Many standard dielectric fittings rely on insulating gaskets to perform sealing duty simultaneously. Under sustained compression these gaskets suffer creep and ageing; once deformed, they trigger both leakage and loss of electrical insulation.

Hikelok seamless dielectric fitting physically separates sealing and dielectric functions. Fluid sealing is handled by FKM sealing assemblies plus PTFE backup rings. The dielectric insulator undertakes electrical isolation only and bears no primary process-medium pressure. This fundamentally prevents mechanical damage to insulating polymer under pressure and greatly mitigates risks of simultaneous sealing-and-insulation failure.

Stable material construction for reliable performance in demanding service

All component parts are manufactured from corrosion-resistant grades, suitable for harsh fluid conditions in oil-gas and chemical industries. It effectively blocks stray current and cathodic-protection current and prevents instrument-loop failures including electrochemical corrosion and measurement-signal drift.

Multi condition adaptation, dual factory testing

Can meet the requirements of oil and gas pressure, process sampling, and instrument monitoring in all scenarios; The integrated pre installation of the product has been completed, and it has undergone special tests for pressure and insulation before leaving the factory. The consistency of the components is good, avoiding assembly defects during on-site assembly.

Lower maintenance cost with superior long-term total-cost-of-ownership

Blocks harmful current intrusion into instrument equipment and protects transmitters and sensors against stray-current-induced galvanic corrosion. It significantly cuts costs for instrument replacement, unplanned shutdown repair and fault troubleshooting for better long-term economy.

 

4. Comprehensive Comparison of Dielectric Fitting

Comparison among three insulating schemes: Hikelok dielectric fitting, conventional insulating flange, and simple split-type insulating fitting. Significant differences exist in applicable scenarios, failure risk and maintenance complexity; cross-application without proper evaluation shall be avoided.

表1

5. Important Notes

Temperature Limitation

When ambient temperature exceeds 93 °C, polymeric insulating materials will soften rapidly and insulation performance degrades significantly. This product is NOT recommended for high-temperature process piping service.

Creep-ageing Risk of Insulating Components

Under sustained pressure and thermal cycling, insulating components will experience gradual creep-ageing with progressive degradation of insulation resistance. Periodic inspection of dielectric performance is required.

No Over-voltage Protection

When subjected to surge, lightning impulse or stray over-voltage, the insulating liner may suffer direct dielectric breakdown with internal carbonization and permanent short-circuit. Device appearance may show no visible damage, yet insulating function is permanently lost and cannot be repaired.

For more ordering details, please refer to the selection catalogs on Hikelok's official website. If you have any selection questions, please contact Hikelok's 24-hour online professional sales personnel.